[Directory] [Data...]

ctd

 PI:              Cindy Lee
 of:              Stony Brook University, Stony Brook, NY (SUNY-SB)
 dataset:         CTD profiles; pres, temp, salinity, etc.
 dates:           8 April 2006 to 13 April 2006  (20060408-20060413) 
 location:        N: 43.418  S: 43.248  W: 7.779  E: 7.995 
 project/cruise:  Medflux/EN416
 platform:        R/V Endeavor
 
 
 Methodology
 
 Change history: YYMMDD
    060724: original CTD data files via email from Joan Fabres (SUNY SB); 
    070213: data prepared by Terry McKee (PO Dept., WHOI) 
            and added to database by Cyndy Chandler, OCB DMO
 
 PI-notes:
    sta  1: First cast of EN416, water for traps
    sta  3: First FGP Pressure cast of EN416, First day of cruise.
    sta 12: morning FGP cast 
 
 DMO Notes: Data were recovered from Seabird-processed .asc data files and are
    reported as 0.5 dbar pressure sorted profiles. CTD sensors corrected using 
    pre-cruise calibrations; only preliminary comparison has been done with 
    in-situ data, e.g. no post-cruise calibration work has been done. Station 19 
    data is from the uptrace portion of the cast.  Use with caution.
 
 
 Parameter     Description                          Units

event unique sampling event YYYYMMDDhhmm date start date of event (GMT) YYYYMMDD time start time of event (GMT) hhmm lon longitude, negative denotes West decimal degrees lat latitude, negative denotes South decimal degrees Pmax pressure, maximum recorded decibars sta station number integer press pressure, from CTD decibars depth depth, from CTD meters temp temperature, from CTD, ITS-90 degrees Celsius (from primary T0 sensor) sal salinity, from CTD, PSS-78 (PSU) dimensionless (from primary T0,C0 sensors) potemp potential temperature, ITS-90 degrees Celsius (from primary T0,C0 sensors) sigma-t sigma T (density) kilograms/meter^3 (from primary T0,C0 sensors) O2_ml_L oxygen, dissolved from SBE 43 CTD ml/liter beam_att Beam attenuation Chelsea/Seatech 1/m trans light transmission percent fluor_ECO fluorescence, from CTD profiler micrograms/meter^3 rescaled, units are numerically equivalent to chlorophyll-a concentrations Pumps status indicator (1=on; 0=off) integer depth_lat depth, from CTD meters with latitude correction sndvel_CM Sound velocity Chen-Millero m/s desc_rate dz/dtM: Descent Rate m/s PAR irradiance Biospherical/Licor microEinstiens/m^2 sec press_fgp0 pressure, voltage output Kpa press_fgp1 pressure, FGP voltage output Kpa cond conductivity, from CTD S/m (from primary C0 sensor) nd indicates missing, bad or no data

This document is created from the content of the info file.

info app: /home/ocb/dbase v.090827 CLC
Data URL: http://ocb.whoi.edu/jg/serv/OCB/MedFlux/EN416/ctd.