Date: 06/11/2007 ASCII file: C:\olga\oc404\ctd\OC404_1_dim_olga_sts_1_2_final.con Configuration report for SBE 911/917 plus CTD --------------------------------------------- Frequency channels suppressed : 0 Voltage words suppressed : 0 Computer interface : RS-232C Scans to average : 1 Surface PAR voltage added : Yes NMEA position data added : Yes Scan time added : No 1) Frequency 0, Temperature Serial number : 4148 Calibrated on : 10-Jan-2004 G : 4.37334110e-003 H : 6.61218005e-004 I : 2.43690559e-005 J : 2.06100587e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 2) Frequency 1, Conductivity Serial number : 2147 Calibrated on : 01-Nov-03 G : -1.03409814e+001 H : 1.44457231e+000 I : -2.76762621e-003 J : 2.55865529e-004 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 3) Frequency 2, Pressure, Digiquartz with TC Serial number : 69685 Calibrated on : 18 dec 2002 C1 : -4.680530e+004 C2 : -8.320595e-001 C3 : 1.450810e-002 D1 : 3.903100e-002 D2 : 0.000000e+000 T1 : 3.038361e+001 T2 : -5.411459e-004 T3 : 4.085080e-006 T4 : 2.564540e-009 T5 : 0.000000e+000 Slope : 0.99995000 Offset : -0.54220 AD590M : 1.280820e-002 AD590B : -9.210198e+000 4) Frequency 3, Temperature, 2 Serial number : 2900 Calibrated on : 10-Jan-2004 G : 4.32911701e-003 H : 6.44107572e-004 I : 2.32868553e-005 J : 2.25293752e-006 F0 : 1000.000 Slope : 1.00000000 Offset : 0.0000 5) Frequency 4, Conductivity, 2 Serial number : 2707 Calibrated on : 08-Jan-2004 G : -1.07300026e+001 H : 1.56055977e+000 I : -1.61614292e-003 J : 2.14476060e-004 CTcor : 3.2500e-006 CPcor : -9.57000000e-008 Slope : 1.00000000 Offset : 0.00000 6) A/D voltage 0, Free 7) A/D voltage 1, User Polynomial Serial number : 013 Calibrated on : 12/09/2002 Sensor name : Fluorometer, Wetlab ECO-AFL/FL A0 : -3.15810000 A1 : 16.31530000 A2 : 0.00000000 A3 : 0.00000000 8) A/D voltage 2, PAR/Irradiance, Biospherical/Licor Serial number : 4600 Calibrated on : 21-Aug-2000 M : 1.00000000 B : 0.00000000 Calibration constant : 357142857.00000000 Multiplier : 1.00000000 Offset : -3.83600000 9) A/D voltage 3, Transmissometer, Chelsea/Seatech/Wetlab CStar Serial number : 537DR Calibrated on : 12/10/2002 M : 21.4097 B : -1.2203 Path length : 0.250 10) A/D voltage 4, User Polynomial, 2 Serial number : ISIS_NO3 Calibrated on : Sensor name : ISUS_NO3 A0 : -3.24600000 A1 : 25.80400000 A2 : 0.00000000 A3 : 0.00000000 11) A/D voltage 5, User Polynomial, 3 Serial number : ISUS_ch2 Calibrated on : Sensor name : ISUS_channel 2 A0 : 0.00000000 A1 : 1.00000000 A2 : 0.00000000 A3 : 0.00000000 12) A/D voltage 6, Oxygen, SBE 43 Serial number : 0264 Calibrated on : 04-Mar-2004 Soc : 4.0150e-001 Boc : 0.0000 Offset : -0.5824 Tcor : 0.0005 Pcor : 1.35e-004 Tau : 0.0 13) A/D voltage 7, Free 14) SPAR voltage, Unavailable 15) SPAR voltage, SPAR/Surface Irradiance Serial number : 6294 Calibrated on : 04/21/97 Conversion factor : 1671.77000000 Ratio multiplier : 1.00000000